GLI GLI Quality Tool
GLI Quality Tool — Version 2.0

Building Reliable TB Sample Tracking in Australian Laboratories

A dependable specimen tracking process gives a tuberculosis laboratory a clear account of every sample from collection to reported result. It reduces the chance of misplaced tubes, transcription errors, delayed testing and uncertain disposal decisions. Whether the system uses printed barcodes, handwritten registers or a combination of both, the purpose is the same: preserve identity and traceability throughout the testing pathway.

A TB sample may pass through reception, biosafety assessment, microscopy, molecular testing, liquid culture, identification, drug susceptibility testing, storage and disposal. Each handover creates an opportunity for an incorrect patient record, an unlabelled tube or a result attached to the wrong accession number. A tracking system makes each movement visible and provides evidence when a result, instrument run or incident needs to be investigated.

For Australian laboratories, the approach must suit the local service model. A metropolitan reference laboratory in Melbourne or Brisbane may receive couriered specimens from many hospitals, while a regional service in the Northern Territory may manage longer transport times and intermittent connectivity. Public, private and hospital laboratories can also use different laboratory information systems, so a practical process needs defined responsibilities, clear paper backups and controls that work during busy shifts.

Define The Specimen Journey

Start by mapping the complete path of a TB specimen, rather than selecting software or labels first. Describe what happens from the request being made through collection, transport, receipt, accessioning, testing, referral, storage and final disposal. Include sputum, tissue, body fluids and any additional specimens relevant to the laboratory’s scope. For every stage, record who handles the sample, what information is captured and what event confirms that the handover occurred.

A useful minimum data set includes a unique accession number, patient identifiers according to local privacy procedures, specimen type, collection date and time, source facility, requested tests, receiving staff member, condition on arrival and current location. The system should also record rejected specimens, recollections, referrals, amended reports, aliquots and linked cultures. Never rely on a patient name alone: names can be duplicated, abbreviated or entered inconsistently.

Set rules for exceptional situations before implementation. A leaking container, an illegible label, an unexpected specimen, a duplicate request or a sample without sufficient volume should receive a defined status and escalation pathway. The original record should remain visible when information is corrected; silently overwriting entries makes later review difficult. In TB work, where results can affect treatment and public health action, an audit trail is essential.

Select Barcodes Or Manual Logs

Barcode tracking is valuable when the laboratory handles a high volume of specimens or needs fast, reliable matching between tubes, worksheets and analysers. A printed barcode can contain a unique accession number without displaying unnecessary clinical information. Staff scan it at reception, aliquoting, testing, storage and dispatch, creating time-stamped records with less manual typing. Labels must be resistant to condensation, refrigeration, disinfectants and routine handling.

A barcode system still needs good design. Use one numbering convention, check that scanners read labels on the intended tube type and prevent duplicate numbers. Define what happens when a label will not scan, a printer fails or the laboratory information system is unavailable. Keep a controlled downtime form or paper register, then reconcile each manual entry against the electronic record when service returns.

Manual logs can be safe and effective in a small laboratory, a low-volume service or a setting where infrastructure is limited. Use bound or controlled pages with preprinted fields, sequential accession numbers, permanent ink and dated staff initials. Corrections should be made with a single line, the corrected entry, initials and date; erasing or using correction fluid removes evidence of what happened. A manual log should be treated as a controlled record, not an informal notebook.

A hybrid model often suits Australian services. For example, a regional laboratory may register a specimen in a paper receipt log during a network outage, then enter it into the laboratory information system after reconnection. The two records must share the same unique identifier, and a supervisor should verify that every downtime specimen has been reconciled. The process should be tested during an ordinary shift, not just described in a procedure.

Connect Tracking With Quality Essentials

Sample identification and traceability sit across several quality management activities, including documents and records, equipment, personnel, process management, assessment and continual improvement. Use the GLI Quality Tool to align the workflow with its phase-specific checklists and the twelve Quality Systems Essentials. This prevents the tracking register from becoming a standalone project disconnected from training, audits, safety and corrective action.

Document the process in a controlled procedure with a simple flow diagram. Include label creation, receipt checks, accessioning, aliquoting, result verification, storage locations, referral packaging and disposal. Link each step to the record that proves it happened. A specimen location code might identify a freezer, rack, box and position, while a culture record can connect the primary sample, aliquot, inoculated medium and final result.

Physical layout affects tracking accuracy and biosafety. Reception, specimen preparation, amplification areas and waste routes should support a logical one-way flow where possible. Review the recommendations in cross-contamination layout guidance when placing benches, scanners, printers, refrigerators and storage racks. A convenient scanner that requires staff to cross a clean area repeatedly may create a bigger risk than it solves.

Equipment and software controls also matter. Assign barcode printers, scanners, computers and temperature-monitored storage units to responsible staff. Record maintenance, calibration, service interruptions and temperature excursions against the relevant equipment or specimen records. A tracking system should show whether a sample was in a validated storage condition, especially when culture or molecular testing is delayed.

Train Staff And Test The Workflow

Training should use realistic specimens and common failure scenarios. Staff need to practise receiving a correctly labelled sample, rejecting an unsuitable one, creating an aliquot, transferring custody and recording a result. Include casual, rotating and courier-receiving personnel, because gaps often arise at the edges of the laboratory rather than at the main testing bench.

For laboratories using MGIT or another liquid culture platform, connect sample tracking training with MGIT use training. Staff should understand how the accession number follows the specimen into the instrument, how positive and contaminated cultures are recorded, and how instrument flags are linked to the correct patient record. Competency should be observed and documented rather than assumed after a presentation.

Run a small pilot before making the process routine. Select a representative mix of specimens and follow each one through receipt, testing, referral and storage. Measure mismatched identifiers, incomplete fields, delayed entries, lost labels, manual workarounds and time taken per specimen. Invite staff to report awkward steps without blame; early feedback often identifies a printer position, screen field or storage code that needs redesign.

Make downtime drills part of the pilot. Disconnect the scanner or laboratory information system for a controlled period and require staff to use the backup log. Then reconcile the records, check for duplicates and confirm that no result was released against an unverified accession number. Record lessons and update the procedure before the full rollout.

Maintain Review And Accountability

Assign ownership at each stage. Reception staff verify identifiers and specimen condition; testing staff confirm the accession number before starting a run; supervisors review exceptions; and authorised personnel release results. A named quality manager should monitor indicators and ensure that corrective actions are completed. Responsibility should remain clear when a specimen is referred to another service or returned from a reference laboratory.

A visual schedule can make recurring checks easier to manage. Use the maintenance task calendar to coordinate scanner checks, label printer servicing, freezer reviews, backup verification, temperature probe checks and software access reviews. Tie each task to a responsible person, due date and record location, rather than relying on memory or informal reminders.

Controls Worth Embedding

Review performance at a frequency suited to workload and risk. Useful measures include the percentage of specimens with complete receipt records, barcode scan failure rate, time from receipt to accessioning, unresolved location discrepancies and the number of amended reports caused by identification errors. Displaying these trends for staff turns tracking into a shared quality responsibility.

The process should also support privacy and information security. Limit access according to job role, store paper logs securely and dispose of labels and printed worksheets through approved confidential-waste arrangements. When specimens move between an Australian hospital, private provider and reference laboratory, document the handover and retain the relevant transport and referral records.

Begin with one specimen pathway, establish the controls, and expand only after the pilot shows that staff can use the system under normal and disrupted conditions. Download the relevant GLI Quality Tool materials, map your current process, and assign an owner for each improvement action. A consistent accession number, a visible audit trail and a practiced backup method will give your TB service stronger assurance from the moment a sample arrives until its record is securely closed.