GLI GLI Quality Tool
GLI Quality Tool — Version 2.0

Building a Reliable TB Laboratory Reagent Log

A clear record of stains, reagents and culture-media components helps a tuberculosis laboratory protect test quality from the moment a product arrives until the final drop is used. Recording lot numbers, expiry dates, opening dates and initial inspection findings creates a practical chain of evidence for microscopy, culture and drug susceptibility testing.

The log can be a controlled paper form, a spreadsheet or part of a laboratory information system. The format matters less than consistency. Every entry should be readable, attributable to a staff member and easy to connect with a specimen batch, test run or nonconformance.

For Australian laboratories, the process should fit the way work is actually delivered. A metropolitan public pathology service in Sydney or Melbourne may receive regular supplier deliveries, while a remote facility in the Northern Territory or Western Australia may need to manage longer transport times, heat exposure and limited replacement stock. The same basic log can support both settings when its fields are designed carefully.

Define The Purpose And Scope

Start by deciding which products require a controlled entry. Include acid-fast stains, decolourisers, counterstains, fluorescent stains, buffers, culture media ingredients, growth supplements, antibiotics, quality-control organisms and reagents used for identification or drug susceptibility testing. Commercial kits should be recorded when their performance depends on a particular lot.

A single log may cover all products, but separate tabs or sections for microscopy, culture and DST can make review easier. Record the product name, manufacturer, catalogue number, lot or batch number, received date, expiry date, storage requirement and supplier. If a product is prepared in-house, add the preparation date, preparer, formula reference and assigned expiry.

The log should support the laboratory’s quality management system rather than create paperwork for its own sake. Link it to document control, stock management, equipment monitoring, internal quality control and corrective action procedures. In a NATA-accredited environment, staff should be able to show how a reagent was accepted, released for use and traced to test results.

Capture The Right Lot Details

Use one line or electronic record for each distinct lot. Do not combine several lots under a general entry such as “Ziehl–Neelsen stain” because that prevents a reviewer from identifying which material was used on a particular day. If a supplier sends two containers with the same lot number, record the container or pack identifier as well.

Useful fields include product name, reagent type, supplier, manufacturer, catalogue number, lot number, date received, quantity received, storage location and expiry date. Add a status field such as quarantined, released, in use, expired or discarded. A controlled dropdown in a spreadsheet can reduce inconsistent wording.

The person who receives the delivery should initial the entry, but the person authorising release should also be identifiable when the risk warrants it. A scanned delivery docket, certificate of analysis or product insert can be referenced by file name or document number. This is particularly useful when a supplier changes labelling or sends a replacement item.

For culture and DST work, a stronger record is often needed because media and reagents can affect a large number of patient results. The record-keeping practices provide a useful model for linking materials, preparation activities, controls and results.

Perform An Initial Inspection

The initial inspection takes place before the product is released for routine use. Check that the container is intact, the label is legible, the lot number matches the delivery paperwork and the expiry date is acceptable. Look for leakage, cracked bottles, damaged seals, unusual colour, precipitation, cloudiness or evidence that a temperature-sensitive item has been compromised.

Write the findings in plain language rather than using a tick alone. “Bottle intact, clear solution, label matches docket” gives a better record than “OK”. If there is a concern, quarantine the item, identify it clearly and notify the senior scientist or quality manager. Do not quietly return a questionable bottle to the shelf.

For prepared stains and media, include a suitability check appropriate to the product. This may involve appearance, pH, sterility, performance with known control material or comparison with an accepted lot. The acceptance criteria should be written in a procedure or work instruction, not invented during the inspection.

A small laboratory in regional Queensland may need to document the condition of a delivery after a long courier journey, particularly during summer. A photo of damaged packaging, a temperature logger reading or a note about delayed transport can help establish whether the issue occurred before the item reached the laboratory.

Record Opening Dates And Use-By Dates

The opening date is different from the date received and should be entered when the seal is first broken or the product is first accessed. Add the initials of the person opening it. If the manufacturer specifies a period after opening, calculate the use-by date and write it on the container as well as in the log.

For products without a clear open-vial stability period, the laboratory should define a local rule using manufacturer information, validation evidence, risk assessment and observed performance. Never assume that the printed expiry date remains valid after opening. Light-sensitive stains, volatile solvents and prepared solutions may have shorter useful lives once exposed to air or repeated handling.

A container label might state: “Opened 14 May 2026, discard 14 August 2026, AB.” The log should carry the same information, with any revised date approved according to the laboratory’s procedure. If a bottle is split into working aliquots, assign each aliquot a traceable identifier and record the parent lot.

Use first-expiry, first-out stock rotation, while keeping newly opened containers separate from those already in use. Staff should be able to see at a glance whether a reagent is available, open, near expiry or awaiting inspection. This reduces waste and makes it less likely that an old bottle will be used during a busy shift.

Link Reagents To Test Quality

A reagent log becomes valuable when it can be connected to quality-control results. For stained smears, record the stain lot and opening date alongside the date of the control run, control material, observed result and reviewer. If performance deteriorates, the laboratory can identify affected slides and investigate quickly. The GLI resource on stained-smear QA guidance can help laboratories build this connection.

For culture media and DST, retain records of preparation, sterilisation, pH checks, growth controls, contamination observations and release decisions. A reagent lot that is associated with failed controls or unexpected growth should be placed on hold while the laboratory assesses the impact.

Where a result has already been reported, the quality manager should determine whether a retrospective review is needed. The review may include patient specimens, control results, instrument records, staff competency and environmental conditions. The aim is to make a defensible decision based on evidence, rather than to blame an individual.

For Australian services, this traceability supports communication between state or territory public health laboratories, hospital networks and reference services. It can also help when a supplier issues a recall or when a remote site needs to explain why testing was paused while replacement material travelled from Perth, Brisbane or a central warehouse.

Control Storage And Ongoing Checks

The log should show where each reagent is stored and what condition applies. Record refrigerator, freezer or room-temperature locations using a consistent identifier. Daily temperature records belong in the relevant equipment log, but the reagent record should cross-reference them when a storage excursion affects product suitability.

During routine use, staff should check the container before dispensing. Look for contamination, evaporation, crystals, colour change and a damaged cap. Add a simple ongoing inspection field if the product is high risk or frequently handled. The person finding a problem should mark the material as quarantined and record the action taken.

pH is especially important when preparing culture media. A meter that is out of calibration can produce media that appears acceptable but supports poor growth or changes test performance. Laboratories should follow a defined calibration and maintenance process, supported by the pH meter calibration guide.

Review the log at a planned interval, such as monthly or during each quality meeting. Look for expired stock, missing opening dates, repeated inspection failures, unused products approaching expiry and lots associated with control failures. Trend these findings to identify ordering, storage or training problems.

Apply Practical Log Controls

A useful form is brief enough to complete during receiving and detailed enough to support an audit. Include a controlled correction method: draw a single line through an error on paper, enter the correct information, add initials and date, and never obscure the original entry. Electronic systems should retain an audit trail.

Use these implementation practices when setting up the register:

Train all relevant staff with a real delivery rather than relying only on written instructions. A short demonstration can cover inspection, labelling, data entry, quarantine and escalation. Supervisors should check a sample of entries during competency assessment and provide prompt feedback when fields are missed.

Keep the current form or electronic template under document control. Displaying an uncontrolled spreadsheet on a shared drive can lead to duplicate versions, overwritten data or inconsistent fields. Protect the master file, define access permissions and back up records in line with the laboratory’s information governance requirements.

A well-maintained reagent register turns ordinary stock handling into useful quality evidence. It shows what was received, what was accepted, when it was opened, how it performed and what happened when a problem was found. Put the log into use with the next delivery, review the first month of entries, and refine the fields until they support safe, traceable TB testing without slowing the bench team down.