GLI GLI Quality Tool
GLI Quality Tool — Version 2.0

Writing a practical TB specimen collection and labelling job aid

A clear job aid can prevent a useful respiratory specimen from becoming unsuitable for testing. For tuberculosis (TB) work, the instructions need to help staff select the right container, label it accurately, protect themselves during collection, and preserve the sample during transport. The document should support busy clinical teams without relying on specialist knowledge or long explanations.

Writing a job aid for TB lab staff on proper specimen collection containers and labeling requires close attention to the whole workflow. A sputum sample may pass through a ward, community clinic, regional courier service and reference laboratory before testing begins. The instructions should therefore be specific enough for consistent practice in a metropolitan hospital, a remote health service or a collection site in a regional Australian town.

Define the job aid’s purpose

Start by stating exactly what the job aid covers. It might apply to expectorated sputum for smear microscopy, molecular testing and culture, while excluding saliva, nasopharyngeal swabs or specimens collected for another purpose. If several specimen types are accepted, describe each one in a separate section so staff do not apply sputum requirements to a different sample.

Set a short list of outcomes near the beginning: collect an adequate lower-respiratory specimen, use a suitable container, apply complete patient and specimen identification, and send the sample promptly under the approved transport conditions. This gives the reader a practical reason to follow each instruction.

Identify the intended users and location. A laboratory collector may already know the local accessioning system, whereas a nurse in an emergency department or Aboriginal Community Controlled Health Service may need clearer guidance on collection timing and handover. Include the laboratory contact number and the local procedure name, but avoid filling the page with information that belongs in a separate policy.

Specify suitable collection containers

Describe the container by its features rather than by a brand. For sputum, the job aid should generally call for a sterile, single-use, leak-resistant container with a secure screw cap, a wide opening and enough capacity for the requested volume. The container should be easy to open and close while wearing gloves, and its material should be compatible with the laboratory’s processing methods.

State the required volume according to the receiving laboratory’s validated procedure. If the laboratory accepts a smaller amount in some circumstances, explain how staff should record that limitation rather than encouraging them to reject every low-volume sample. The wording should distinguish a genuinely inadequate sample from a specimen that is simply below an ideal target.

Tell staff what must not be used. Examples may include urine pots without laboratory approval, containers with loose-fitting lids, cracked or visibly damaged vessels, previously opened containers and improvised household jars. Avoid vague wording such as “use an appropriate pot”; staff need to recognise the approved container at a glance.

Add a visual cue if possible. A photograph or simple drawing can show the correct lid, fill level and label position. Make sure the image matches the stock actually supplied at the site. Australian laboratories may purchase consumables through different hospital networks, government contracts or rural suppliers, so a generic image should not create confusion about the approved product.

Make labelling unambiguous

The label should identify the person and the specimen without relying on the request form alone. At a minimum, include the patient’s full name, a second identifier such as date of birth or medical record number, the date and time of collection, and the specimen type. Include the collector’s identifier if required by the local laboratory information system or policy.

Explain that the label belongs on the container, not just on the transport bag. It should remain readable if condensation forms on the outside, and it must not cover the lid, obscure the specimen or prevent laboratory staff from checking the container. A waterproof label or permanent marker approved for laboratory use is preferable to a paper sticker that detaches in a chilled esky.

Include a direct instruction for label verification. The collector should compare the identifiers with the patient and the request form before leaving the collection area. Where policy permits, use two approved identifiers and document the collection time immediately. The job aid should also explain what to do if the label is missing, incomplete, contradictory or placed on the wrong container: stop processing, isolate the specimen if necessary and contact the responsible laboratory staff member.

Do not suggest that staff “fix” an identification error from memory. A correction made without a traceable process can create a serious patient-safety event. The job aid should point to the local rejection, recollection and incident-reporting procedure.

Cover collection and handover

Use plain, action-based language for the collection steps. Staff should explain the procedure to the patient, move to a well-ventilated or designated area, and ask the patient to produce a deep cough specimen from the lower airways rather than saliva. The patient should keep the container upright, avoid touching the inside or underside of the lid, and close it firmly as soon as collection is complete.

The aid should state whether the patient must provide one or more specimens and when they should be collected. Requirements vary by testing pathway and local policy, so link the instruction to the current laboratory request form rather than embedding an outdated schedule. If a patient cannot produce sputum, staff should follow the approved clinical pathway instead of substituting saliva without advice.

Describe the handover sequence: check the container and label, place the container in the primary leak-resistant packaging, complete the request form, and record collection and dispatch details. The request form and container should be matched before the specimen leaves the collection point. A simple “container, label, form” check can work well at a busy reception desk.

For sites in Australia, include realistic handover conditions. A specimen from a Melbourne hospital may reach the laboratory within hours, while one from a remote Northern Territory or Western Australian service may depend on scheduled road or air transport. The job aid should tell staff whom to contact when the routine courier has departed, the sample cannot be refrigerated as directed, or a delay could affect testing.

Build in safety and transport controls

TB specimen collection can generate infectious aerosols. The job aid should direct staff to follow the facility’s respiratory protection, ventilation and personal protective equipment requirements. It should make clear that the container is closed before it is removed from the collection area and that staff must perform hand hygiene after glove removal and after handling the specimen.

Transport instructions must match the receiving laboratory’s approved packaging system. In Australia, diagnostic specimens may need packaging and documentation consistent with applicable dangerous goods requirements, including the relevant arrangements for UN3373 Biological Substance, Category B where that classification applies. The job aid should not ask general staff to make a classification decision unless they have been trained to do so; instead, it should refer them to the local packaging and transport procedure.

Explain what to do with a leaking, cracked or contaminated container. Staff should not wipe a leaking vessel and send it forward as if it were acceptable. The procedure should identify the safe containment method, the person to notify, the cleaning response and the process for requesting a recollection. Add an after-hours contact pathway because incidents often occur outside standard laboratory opening times.

Storage instructions should be precise. State whether the sample should be refrigerated, protected from freezing or sent at ambient temperature, and identify the maximum holding time validated by the laboratory. A common household habit such as placing a sample in a shared staff refrigerator is unsafe and should be explicitly prohibited.

Test the instructions in practice

Before approval, observe several staff members using the job aid without coaching. Watch for points where they hesitate: finding the correct container, entering the collection time, closing the lid, placing the label or preparing the transport bag. These observations reveal workflow problems that a desk review may miss.

Test the document with people who have different levels of experience and different first languages. Ask them to demonstrate the process rather than simply confirming that the wording looks clear. In a regional service, also test whether the instructions remain practical when supplies arrive in a different carton or when courier collection occurs only once daily.

Use a short scenario-based check. For example, ask staff to respond to an unlabeled specimen, a container with saliva only, a leaking lid and a patient who cannot produce sputum. The correct response should be easy to find in the job aid, with no need to search through a lengthy quality manual.

Keep the layout usable at the point of work. Use large enough text, high contrast, short steps and a clear distinction between “do this” and “stop and contact the laboratory.” A laminated copy near the collection area may be useful, while a controlled electronic version can be updated when the laboratory changes its container, courier or information system.

Connect the aid to quality improvement

Treat the job aid as a controlled quality document. Add a document number, version, approval date, review date, owner and references to related procedures. The laboratory quality manager should confirm that the container requirements, labelling rules, safety measures and transport instructions match current practice.

Define a small set of measures to determine whether the aid works. Useful indicators include rejected TB specimens caused by missing identifiers, wrong containers, leakage, insufficient volume or delayed transport. Review the results by collection location where possible; a single metropolitan department may have a different problem from a remote clinic using the same form.

Use incidents and staff feedback to revise the aid. If several samples arrive with collection times missing, the problem may be a poorly placed field on the request form rather than carelessness. If containers leak during courier transport, investigate stock quality, cap closure and packaging before rewriting the same instruction.

The microscope troubleshooting job aid offers a useful model for presenting practical actions, decision points and escalation steps. For broader document control and implementation checks, align the work with the GLI Quality Tool’s quality system checklists, adapting the prompts to the laboratory’s setting and resources.

A well-designed job aid turns specimen collection from an assumed routine into a consistent, auditable process. Place the approved version where collection occurs, brief all relevant staff, monitor rejection data and review the document whenever containers, transport arrangements, regulations or testing pathways change. This keeps TB specimens identifiable, safe to handle and suitable for timely laboratory diagnosis.