Safe handling and storage of TB test kits and reagents
Reliable tuberculosis testing begins long before a specimen reaches an analyser. Every test kit, reagent, control, calibrator and consumable must be received, stored, prepared and used in a way that protects performance and staff safety. A small lapse in temperature control or stock rotation can produce an invalid result, delay treatment and waste a scarce laboratory resource.
This guide is intended for staff working with molecular, culture, smear microscopy and other TB-related laboratory methods. Local procedures must always follow the manufacturer’s instructions for use, the laboratory’s approved documents, and applicable Australian requirements. The same principles apply in a metropolitan hospital, a public health reference laboratory or a small service supporting remote communities.
Good storage practice is part of a wider quality management system. The GLI Quality Tool provides practical resources for laboratories building consistent processes across safety, equipment, documentation, assessment and continual improvement. Use this guidance alongside your facility’s risk assessments, training records and quality indicators.
Receiving kits and reagents
Assign responsibility for receiving laboratory supplies. The authorised staff member should check the delivery promptly, especially when a shipment contains temperature-sensitive reagents. Compare the order with the packing slip and record the product name, catalogue or lot number, quantity, expiry date, arrival date and storage condition.
Inspect every package for broken seals, leaks, crushed cartons, moisture, contamination or evidence of thawing. For chilled or frozen goods, review the temperature indicator or data logger where supplied. A box that feels cold is not evidence that the required temperature was maintained. If a shipment is warm, damaged or incomplete, quarantine it, label it clearly and notify the supplier or procurement team before use.
Australian laboratories may receive supplies through state health procurement arrangements, private distributors or specialist couriers. Deliveries to regional Western Australia, the Northern Territory or far north Queensland can take longer and may be exposed to high ambient temperatures during transport. Make sure delivery instructions include a staffed receiving point and a plan for weekends, public holidays and remote site transfers.
Do not accept an apparently compromised kit simply because testing is urgent. Record the problem as a nonconformance, retain relevant packaging and seek a documented decision from the laboratory manager or quality officer. This preserves traceability and helps identify repeated courier or supplier failures.
Storing supplies under controlled conditions
Keep reagents in the temperature range stated by the manufacturer, using a monitored laboratory refrigerator, freezer or room-temperature storage area as appropriate. Do not place kits in a domestic refrigerator used for food, drinks or staff lunches. Food storage creates contamination risks and makes temperature responsibilities difficult to demonstrate.
Use calibrated or verified thermometers, and record minimum and maximum temperatures at a defined frequency. Digital monitoring with an alarm can be valuable, but it does not replace a documented response when an alarm occurs. Establish instructions for power failure, equipment breakdown and prolonged temperature excursions, including where stock will be moved and who can approve its release.
Separate unopened stock from prepared reagents, clinical specimens and materials awaiting disposal. Store chemicals and reagents in a way that prevents spills from contaminating labels or neighbouring products. Light-sensitive materials should remain in their original packaging or a suitable opaque container. Keep shelves orderly, with enough space for air circulation and cleaning.
Apply first-expiry, first-out rotation rather than relying on the newest delivery being placed at the front. Review expiry dates routinely and avoid opening a new box while an older, suitable box remains available. In Australia, long procurement lead times can encourage over-ordering, but excessive stock increases the chance of expiry and ties up the laboratory budget.
Preparing and using test materials
Before opening a kit, confirm that the product is intended for the specific platform, assay version and specimen type in use. Check the lot number, expiry date and required preparation steps. Allow refrigerated or frozen components to equilibrate only for the time specified by the manufacturer. Repeated freeze-thaw cycles can damage enzymes, controls and other sensitive materials.
Use clean, designated work areas and wear the personal protective equipment specified by the risk assessment. Change gloves when contaminated and avoid touching reagent caps, pipette tips or internal surfaces. Use calibrated pipettes and the correct tips, and do not return unused reagent to its original container. These simple controls reduce carry-over, contamination and incorrect volumes.
Label aliquots and prepared solutions with the name, concentration where relevant, lot number, preparation date, expiry or discard date, storage condition and initials of the person who prepared them. If the manufacturer gives a shorter in-use period than the unopened expiry date, follow the shorter period. A handwritten label should remain legible after refrigeration, freezing or exposure to disinfectant.
Include positive, negative and internal controls as required by the assay and the laboratory’s approved procedure. Do not report patient results when control performance is unacceptable. Investigate whether the cause is a degraded reagent, an instrument problem, contamination, an operator error or an environmental issue before testing resumes.
Managing stock, records and traceability
A stock register should show what is available, where it is stored and when it should be used or removed. At a minimum, record receipt, lot number, expiry, quantity, storage location and disposal. Electronic inventory systems are useful, but paper logs can work well when they are kept current and reviewed by an assigned person.
Traceability must connect the reagent lot to the testing event and, where relevant, to the patient or specimen identifier. Laboratory information systems may capture some of this automatically, while smaller services may need a controlled worksheet. The record should allow an investigation team to identify affected runs if a manufacturer issues a recall or a quality problem is discovered.
Quarantine expired, damaged, recalled or questionable materials in a clearly marked area. Never leave them on an active reagent shelf where they could be selected by mistake. Disposal must follow local biosafety, chemical waste and environmental requirements. If materials have contacted infectious specimens, the laboratory needs a validated decontamination and disposal process; the GLI resource on autoclave waste decontamination can support protocol development.
Review usage and wastage trends at regular quality meetings. A rise in discarded kits may indicate inaccurate demand forecasting, poor rotation, unreliable refrigeration or an assay that is being used outside its intended workflow. Corrective action should address the cause rather than simply ordering more stock.
Responding to temperature excursions and incidents
When a refrigerator, freezer or storage room falls outside its approved range, protect the materials first. Keep the door closed if this may stabilise the temperature, move stock to a validated backup unit when necessary, and record the time, temperatures and products affected. Mark the stock as quarantined until a competent person has assessed it.
The assessment should consider the product, temperature reached, duration of exposure, number of excursions and manufacturer advice. Some reagents can tolerate a brief deviation, while others may be unusable after a single freeze or warming event. Do not make a release decision based on appearance alone; degraded reagents can look normal.
Document incidents, actions and final decisions. If patient testing may have been affected, inform the laboratory director or senior scientist and follow the procedure for result review, repeat testing or notification. A nonconformance record is valuable evidence that the laboratory identifies risk and learns from failures.
Australian sites should include local contingencies. A regional laboratory may lose power during a storm, while a remote clinic may depend on a generator and a scheduled aircraft or road courier. Confirm who can access backup storage after hours, how temperature data will be retrieved and how urgent replacement stock will be obtained through the state or territory network.
Building a dependable local procedure
Turn these practices into a controlled procedure that staff can follow during a busy shift. It should cover ordering, receipt, inspection, storage, preparation, labelling, inventory, temperature monitoring, excursions, recalls, disposal and reporting. Include responsibilities for scientists, technicians, couriers, stores staff, supervisors and the quality manager.
Train new and existing staff using the actual refrigerators, kit labels, monitoring devices and forms used at the site. Observe critical tasks, such as receiving a cold shipment or responding to an alarm, and record competency assessment. Refresher training is especially important when an assay, platform, supplier or storage area changes.
Use the GLI quality management resources to connect reagent control with broader laboratory processes. Internal audits can examine whether staff follow expiry rotation, whether temperature records are complete, and whether quarantined materials remain separated. External assessment and peer review can identify weaknesses that routine checks miss.
Continual improvement should be practical and measurable. Suitable indicators include the percentage of temperature records completed, the number of expired kits discarded, excursion response time, invalid control rates and the proportion of staff assessed as competent. Review trends rather than treating each result as an isolated event.
For laboratories ready to strengthen their overall system, the GLI phase 4 guidance supports sustained quality improvement and integration of lessons into routine operations. A well-maintained reagent process should remain workable during staff leave, equipment failure, seasonal demand and changes in testing volume.
Adopt the procedure at your site, assign clear responsibilities and begin with a documented review of storage areas, temperature records and current stock. Correct immediate risks, train the team, and monitor the agreed indicators through regular quality meetings so every TB test is supported by safe, traceable and fit-for-purpose materials.