An internal audit gives a tuberculosis laboratory a structured way to compare daily practice with its quality management system. It is more than a search for errors. Done well, it shows whether procedures are understood, records are reliable, risks are controlled and improvement work is producing measurable results.

The GLI Quality Tool supports this process through a four-phase roadmap built around the twelve Quality Systems Essentials. Its phase-specific checklists help a laboratory judge where it currently stands and identify the next practical step, whether that involves laboratory safety, staff competency, equipment control, documentation or continual improvement.

For Australian laboratories, the audit should fit the local operating environment. A metropolitan service in Sydney, Melbourne, Brisbane or Perth may have dedicated quality staff and specialist testing platforms, while a regional or remote laboratory may share personnel across several disciplines. Public pathology networks, state and territory TB programmes, NATA expectations and referral arrangements all influence how evidence is collected and acted upon.

The strongest audits are fair, evidence-based and proportionate to risk. They include the people who perform the work, recognise the realities of shift coverage and transport, and treat findings as opportunities to strengthen patient and staff safety. The GLI checklists provide the framework; the laboratory team supplies the local knowledge.

Define The Audit Scope

Start by deciding what the audit needs to establish. A full quality management system review may examine all twelve Quality Systems Essentials, while a focused audit could assess specimen reception, smear microscopy, culture, molecular testing, biosafety or result reporting. Set a clear purpose, such as checking readiness for a service expansion, preparing for an external assessment or verifying that corrective actions have worked.

Select the relevant GLI phase checklist before collecting evidence. A laboratory should use the phase that reflects its current level of development rather than automatically choosing the most advanced phase. The purpose is to identify realistic gaps and build capability progressively, not to create a paper exercise that staff cannot sustain.

Define the audit boundaries in writing. Include the sites, benches, shifts, tests, records and time period covered. If specimens move between a rural collection point and a central laboratory, decide whether transport, referral and communication processes are within scope. Assign an audit lead who is independent enough to review the work objectively, while ensuring that technical experts are available to explain specialised procedures.

Prepare People, Records And Timing

Review the checklist and gather the documents needed to test each requirement. These may include the quality manual, standard operating procedures, training files, equipment maintenance logs, temperature charts, internal quality control records, incident reports, stock records, safety inspections and previous audit reports. Avoid collecting documents simply because they exist; each item should help demonstrate how the system operates in practice.

Plan interviews and observations around actual workflow. An auditor who visits only during a quiet weekday morning may miss problems associated with weekends, night duty, handover or high workload. In Australia, laboratories may operate across several hospitals or use rotating staff from a wider pathology network. A workload distribution framework can help the audit team examine whether duties are allocated safely across shifts rather than assuming that the roster reflects real demand.

Tell staff what will happen and what will not happen. Explain that the audit assesses processes, not individual worth. Provide the schedule in advance, protect time for interviews and invite staff to identify workarounds that are not visible in formal documents. This is particularly important in smaller services, where the person being interviewed may also be responsible for stock control, equipment checks and result entry.

Work Through The GLI Checklist

Use each checklist item as a prompt for three forms of evidence: documents, observation and discussion. A procedure may state that all positive controls are reviewed daily, but the auditor should also inspect recent control records and ask a scientist to describe what happens when a control fails. Agreement between these evidence sources gives confidence that the quality system is embedded.

Record the status of every item consistently. Useful categories include compliant, partially implemented, not implemented, not applicable and unable to verify. Add a short evidence note for each decision. “Procedure available” is weak evidence; “current procedure observed at the bench, staff member explained the escalation pathway, and three recent records matched the requirement” is much stronger.

Move through the Quality Systems Essentials in a logical sequence. Begin with organisation, personnel and safety, then examine equipment, purchasing and inventory, process control, information management, documents and records, assessment and continual improvement. The order can be adapted to the phase checklist, but related findings should be connected so that the audit reflects how the laboratory actually works.

Test Practice At The Bench

Observation is essential because laboratory quality is created during routine work. Watch specimen identification, acceptance and rejection, biosafety precautions, decontamination, workflow separation, result verification and waste disposal. Ask staff to demonstrate a task where appropriate, rather than relying only on a verbal description. Keep the observation respectful and avoid interrupting critical procedures.

Sample records across different dates, staff members and shifts. Check whether entries are complete, legible or electronically traceable, made at the required time and reviewed by an authorised person. For molecular TB testing, examine how run validity, controls, invalid results and repeat testing are documented. For culture or microscopy services, look at incubation monitoring, contamination records, reading schedules and communication of significant results.

Trace a specimen from receipt to final report where possible. This reveals gaps between departments, databases and referral services that may not appear in individual procedures. Include pre-analytical and post-analytical steps, such as collection instructions, transport conditions, urgent notifications and amended reports. In remote parts of Australia, distance, courier schedules and extreme weather can affect turnaround times, so these factors should be assessed as system risks rather than treated as staff failures.

Analyse Findings And Set Priorities

Classify findings according to patient safety, staff safety, regulatory exposure, result reliability and operational continuity. A missing signature may require correction, but an uncontrolled biosafety cabinet, expired reagent or unverified result amendment deserves urgent attention. Use a simple risk approach that considers severity, likelihood and the strength of existing controls.

Write findings in a way that supports action. State the requirement, describe the objective evidence, explain the risk and identify the process involved. For example: “The equipment log did not show completion of scheduled maintenance for the centrifuge used in specimen processing, creating uncertainty about safe and reliable operation.” Avoid personal language, unsupported assumptions and vague statements such as “staff need to be more careful.”

Agree on corrective actions with the people who own the process. Each action should have a responsible person, due date, required resources and a method for checking effectiveness. Some improvements may involve updating a form or retraining staff; others may require procurement, roster changes, a service contract or escalation to the state laboratory network. Document any accepted risk when immediate correction is not possible.

Practical Priorities For Audit Follow-Up

Verify Improvement And Keep The Cycle Active

An audit is incomplete until corrective actions are checked. Set a follow-up date based on risk: urgent safety matters may require verification within days, while a documentation improvement may be reviewed after several weeks of routine use. Look for evidence that the revised process works, not merely evidence that a document was updated.

Use indicators to monitor sustained performance. Suitable measures might include rejected specimen rates, contamination rates, invalid molecular test rates, turnaround times, critical result notification compliance, equipment downtime, incident closure and completion of competency assessments. Compare results over time and investigate unexpected changes rather than selecting only favourable data.

Share the findings with the whole team in a clear, non-punitive format. A monthly quality discussion can review open actions, recurring errors, incidents and indicators; guidance on a monthly quality meeting can help laboratories make these conversations focused and useful. In a busy Australian service, a short meeting with a written action record may be more effective than an occasional lengthy presentation.

Close the audit by updating the improvement register and linking findings to management review. Repeated issues may indicate an unsuitable process, inadequate staffing, poor communication or insufficient resources rather than isolated non-compliance. Use the next GLI phase when the laboratory has demonstrated stable performance and is ready to strengthen its system further.

Use the GLI Quality Tool checklists to schedule the audit, involve the right staff and turn observations into verified improvements. Download the relevant materials, adapt the evidence plan to your laboratory’s size and location, and begin with the highest-risk processes. A disciplined internal audit can make TB testing safer, more consistent and more dependable for patients across Australia.