GLI GLI Quality Tool
GLI Quality Tool — Version 2.0

Creating a practical monthly TB laboratory quality report

A monthly quality report gives tuberculosis laboratory teams a structured way to show whether testing is safe, timely, reliable and aligned with public health needs. It translates routine records into information that managers, clinicians, government programmes, accreditation bodies and funding partners can use.

A good report should be brief enough for busy decision-makers in Sydney, Melbourne, Brisbane or a regional health service, while retaining enough evidence for follow-up. It should present trends, explain exceptions and assign actions, rather than simply listing the number of specimens processed.

Define the report’s purpose and audience

Before building the template, identify who will read it and what decisions they need to make. A laboratory manager may need staffing and equipment information, while a public health unit may focus on turnaround time, drug resistance findings and notification pathways. Hospital executives may want assurance that risks are controlled and resources are being used appropriately.

The report should cover the previous calendar month, state the reporting period clearly and identify the laboratory, reporting officer and date of issue. Include a short management summary at the beginning with three elements: what went well, what requires attention and what decision or support is needed.

For Australian laboratories, the audience may extend across state and territory systems. A metropolitan service could report to a hospital network and local public health unit, while a remote service may need to explain courier delays, limited staffing or referral arrangements. Keep the core format consistent, but allow local fields for jurisdictional requirements and service conditions.

Report area Measures to include Management value
Workload Specimens received, tests performed, referral numbers Shows demand and capacity
Turnaround time Median and percentage within target Identifies service delays
Quality control Controls run, failures, corrective actions Demonstrates analytical reliability
Safety Incidents, exposures, waste and facility issues Supports risk reduction
Equipment Downtime, maintenance and unresolved faults Guides service continuity
Personnel Staffing, training and competency status Reveals capability gaps
Improvement Open actions, overdue items and outcomes Tracks accountability

Select indicators that explain performance

A useful monthly quality report combines activity, quality and outcome indicators. At minimum, record the number of samples received, rejected, tested, referred and pending. Separate respiratory specimens from other sample types where this distinction affects workflow or interpretation.

Turnaround time should be measured from a defined starting point, such as specimen receipt or registration, to a defined endpoint, such as result authorisation or dispatch. Report the median, the percentage meeting the laboratory target and the longest delays. A single average can hide a small number of clinically important late results.

Include indicators for smear microscopy, nucleic acid amplification testing, culture and drug susceptibility testing where these services are provided. Useful measures may include contamination rates, invalid or indeterminate results, repeat testing, external quality assessment performance and the proportion of results communicated within the required timeframe.

Avoid creating a dashboard crowded with figures that nobody reviews. Each indicator should have a definition, data source, target or reference point, reporting owner and explanation of what action follows if performance moves outside expectations.

Connect workload with capacity

Workload data becomes more useful when it is compared with available staff time, instrument capacity and referral commitments. Record monthly volumes alongside the number of rostered staff, vacancies, overtime, leave, instrument hours and significant interruptions. This helps management distinguish a process problem from a sustained capacity problem.

A rise in specimens does not automatically mean the laboratory is inefficient. Demand may be seasonal, linked to an outbreak investigation, increased screening in a vulnerable population or a change in referral patterns. Conversely, a stable workload can still create delays if experienced staff are absent or an analyser is unavailable.

When reviewing workload, examine the complete pathway from collection and transport to reporting. In Australia, long distances and scheduled freight can materially affect rural and remote services, while city laboratories may experience congestion during peak hospital collection periods. A workload analysis guide can help teams connect activity data with staffing, workflow and efficiency decisions.

Report safety, equipment and infrastructure

Laboratory safety should have a visible place in the report, even when there were no incidents. Record biological exposures, spills, near misses, injuries, waste issues, ventilation concerns and corrective actions. A zero-incident month is meaningful only when staff know how to report hazards and supervisors have reviewed the records.

Include biosafety cabinet certification, room pressure or ventilation checks where applicable, autoclave monitoring, emergency equipment checks and unresolved facility faults. Describe any interruption to containment or testing, including the duration, specimens affected and interim control.

Equipment reporting should distinguish planned maintenance, unplanned downtime, calibration issues and consumable shortages. State whether service continuity was maintained through backup instruments, referral testing or altered rosters. This level of detail supports risk-based decisions and gives management a clear reason for replacement, servicing or additional stock.

Australian laboratories operate within workplace health and safety duties set through applicable state or territory legislation. The report does not replace a formal incident system, but it provides a monthly management view of recurring risks and overdue controls.

Show competence and document control

The template should include personnel changes, induction, training completed, competency assessments due and competency assessments overdue. Record whether staff are authorised for specific procedures, including high-risk or technically demanding activities. A short narrative can explain how leave, turnover or agency staffing affected service delivery.

Document control indicators may include new or revised standard operating procedures, documents due for review, obsolete copies removed and staff acknowledgement of critical changes. Link significant procedure changes to training or competency evidence so the report shows that implementation occurred, rather than merely recording approval.

A concise personnel and document checklist can keep this part consistent:

For laboratories working toward accreditation or strengthening an existing quality management system, these records align with the Quality Systems Essentials covering personnel, documents and records, equipment and assessment. They also make internal review easier when a manager needs evidence behind a reported result.

Analyse nonconformities and corrective actions

A monthly report should summarise errors and deviations without turning the document into a blame register. Classify events by stage, such as pre-analytical, analytical, post-analytical, safety, equipment or documentation. Include the number of events, their impact, immediate containment and whether a root cause review was required.

Track corrective and preventive actions in a simple register. Each item should have an owner, due date, risk rating, current status and evidence of effectiveness. Avoid closing an action merely because a new instruction was issued; check whether the change reduced recurrence or improved the relevant indicator.

A useful action summary can focus attention on unresolved risk:

Protect confidentiality by excluding patient names, Medicare details and unnecessary identifiers from the management report. The Privacy Act 1988 and local health information requirements should guide access, storage and distribution. Use aggregated data unless a specific incident review requires controlled individual-level information.

Present trends and decisions clearly

A strong report uses trend comparisons rather than isolated monthly figures. Show the current month against the previous month, the same period last year where available, and the agreed target. Add a short explanation for every material change, especially where performance improved or declined.

Use simple charts sparingly. A run chart for turnaround time, a bar chart for workload and a status summary for corrective actions are usually sufficient. Colour should support interpretation but should not be the only way information is conveyed, particularly when reports are printed or viewed by people with colour-vision differences.

Structure the management summary around decisions. For example, state that culture turnaround exceeded target because of instrument downtime, that a replacement part is awaiting procurement, and that interim referral testing is in place. This is more useful than writing that “performance was below expectations”.

Resources from the GLI Quality Tool can support a consistent reporting process, including downloadable quality resources for laboratories establishing or improving a quality management system. Adapt any checklist or worksheet to local governance, terminology and reporting obligations rather than copying it without review.

Make the next report actionable

A monthly report should finish with a compact action plan covering the next reporting period. Identify the two or three most important risks, name the responsible person, set a due date and state the evidence that will demonstrate completion. Include any request for funding, staffing, maintenance or programme support in plain language.

The laboratory manager should review the draft with relevant section leads before distribution, then retain the approved version according to the document-control procedure. Over time, compare successive reports to see whether actions are reducing delays, improving reliability and strengthening staff capability.

Use the template as a living management tool: agree the indicators, define them once, collect data consistently and review the format after several reporting cycles. When the report connects laboratory evidence with clear decisions, it becomes a practical part of TB service governance rather than another administrative task.